The district heating sector is characterized by sustainability and ecological responsibility. Through the efficient use of energy sources in central power plants as well as waste heat from industry and the subsequent distribution of heat via well-developed district heating networks, district heating makes an important contribution to reducing CO₂ emissions and conserving fossil resources.

District heating systems are divided into the areas of heat generation and distribution, each of which places its own requirements on the components used:

  • Heat generation (power stations): Valves with large nominal diameters and high temperature resistance.
  • Distribution (district heating networks): Solutions for safe, efficient heat transfer to the end consumer.

Kähler offers high-quality valves for both areas of application and ensures that the entire district heating infrastructure - from generation to distribution - can be operated in a well thought-out and sustainable manner.

Discover Products

Why are ball valves particularly suitable for district heating?

Maximum tightness
The design of the ball valves ensures complete tightness both within the system and to the outside. This reliably prevents leaks and the system remains safe and efficient in operation.
Robust, durable and reliable
Ball valves are designed for extreme operating conditions and can withstand both high temperatures and pressure loads, making them ideal for the requirements of district heating generation and distribution.
Double block and bleed with test valve
Our trunnion-mounted ball valves have the “double block and bleed” function, which is characterized by two independent seals. This means that the ball valve acts as a double shut-off, offering maximum safety. There is a test valve between the two seals, which makes it possible to safely check and release the pressure in the isolated area. This function ensures that potential leaks can be detected at an early stage - ideal for reliable leak testing and maximum operational safety.
Optimized energy efficiency
Our ball valves are caracterised by minimal flow resistance, allowing the medium to be transported without significant pressure losses. This increases the overall energy efficiency of the system and reduces energy consumption.

In der Fernwärmeversorgung gibt es grundsätzlich eine Vielzahl an Armaturentypen, die für verschiedene Einsatzbereiche ausgelegt sind. Neben Kugelhähnen kommen auch Absperrklappen, Ventile, Schieber und metallisch dichtende Kükenhähne zum Einsatz:

  • Absperrklappen bieten eine platzsparende Lösung und eignen sich besonders für Anwendungen mit begrenztem Bauraum. Sie verursachen jedoch durch die Klappenscheibe im Durchgang einen erhöhten Strömungs-widerstand, was zu schlechteren Durchflusswerten führt und die Energieeffizienz beeinträchtigen kann. Zudem schließen sie nicht so zuverlässig dicht, was zu möglichen Leckagen führen kann.
  • Ventile ermöglichen eine präzise Steuerung des Durchflusses, sind jedoch aufgrund des erhöhten Widerstands und der weniger guten Durchflusswerte energieintensiver. Sie erfordern außerdem regelmäßige Wartung, da sie anfällig für Verschleiß sind.
  • Schieber bieten eine gute Dichtheit und werden häufig in Anwendungen mit langsamer Öffnungs- und Schließfunktion verwendet, vor allem bei größeren Nennweiten. Allerdings können sie im Betrieb durch Verschmutzungen undicht werden, was ihre Zuverlässigkeit beeinträchtigen kann.
  • Metallisch dichtende Kükenhähne zeichnen sich durch ihre hohe Temperatur- und Druckbeständigkeit aus und sind auch in großen Nennweiten verfügbar. Sie bieten eine gute Dichtheit, sind jedoch teurer und wartungsintensiv, was die Betriebskosten erhöht.

Kugelhähne hingegen bieten eine unschlagbare Kombination aus Dichtheit, Effizienz und Wartungsfreiheit, was sie zur bevorzugten Wahl für Fernwärmeanlagen macht.

Warum sich in der Fernwärme überwiegend Kugelhähne durchgesetzt haben und wo Kükenhähne weiterhin ihre Berechtigung haben, steht im Vergleich Kükenhahn oder Kugelhahn.

Arrange a consultation

Phone +49 (2174) 7848 - 0 | Email: info@kaehler-armaturen.de

Zapfengelagerte Kugelhähne – Produktserie mit Höchstleistung aus dem Hause Vexve

Why Vexve valves for district heating?

We don't have just any ball valves, but the high-quality valves from Vexve, which have been specially developed for the requirements of district heating. Vexve products are characterized by a sophisticated design and numerous advantages that make installation and operation efficient and safe:

High-quality workmanship
Vexve valves are manufactured from first-class materials and offer exceptional durability that is ideally suited to the high demands of the district heating industry.
Short delivery times
Vexve relies on efficient supply chains and short delivery times to cover your project requirements quickly and reliably.
Good insulating properties
The valves can be excellently insulated, which minimizes heat loss and thus contributes to the efficiency of the entire system.
Easy installation thanks to reduced weight
The Vexve design is optimized to reduce the weight of the valves as much as possible. This simplifies installation and handling on site, saving time and money.

With Vexve, you get valves that are specially tailored to the requirements of energy suppliers, municipal utilities and engineering firms and offer a sustainable, reliable solution for your district heating projects.

Why Kähler?

Kähler is your reliable partner in the district heating industry - with an uncompromising focus on quality, service and speed.
Our expertise and our commitment to district heating set us apart:

Fast response time
We know how important time is in your projects. That's why we usually provide you with a customized quote within 2 hours, so you can plan quickly and accurately.
In stock for fast delivery times
Thanks to our extensive warehouse, we are able to deliver many products directly from stock. This means we can guarantee short delivery times and support your projects on time.
District heating experts
District heating is our total focus. With our expertise, association memberships and the hot tapping service as a special service, we offer you comprehensive competence and customized solutions for your district heating projects.
Lifelong support
Kähler's service does not end with delivery. We look after the products we supply for their entire life, even well after the warranty has expired. Your trust is our motivation and your satisfaction is our goal.

With Kähler, you are choosing a partner who will support your district heating projects with expertise, flexibility and comprehensive service - for long-term, reliable cooperation.

What Vexve says about us:

„We have a strong, long-standing and reliable partnership with KÄHLER Industrie-Armaturen, based in Burscheid. As the representative of the Vexve Armatury Group for the German market, KÄHLER not only has a wide range of valves for district energy networks, but also offers a hot tapping service with selected Vexve products. KÄHLER is characterized by extensive expertise, a wealth of experience and a broad network in the energy sector, making it a highly qualified and valuable partner for Vexve.“

Testimonials

What our customers say about us.

In 2019, we had Kähler certify us in hot tapping pipes up to DN 100 that were already in operation. The service and cooperation were simply good. We had dimensions over DN 100 several times, so we had to use Kähler's service. That also worked extremely well.

Bonn Netze

We have been a customer of Kähler Armaturen for years and have nothing but positive things to say: competent advice, fast delivery, top quality, reasonable price-performance ratio, professional hot tapping work and friendly and helpful staff. What more could you want?

Energieversorgung Leverkusen

We in the district heating department are extremely satisfied with the cooperation with Kähler-Armaturen, the processing of orders and the fast delivery times are excellent. They are quick to respond and help with technical information. We also greatly appreciate the friendly cooperation.

Netze Duisburg GmbH

We would be happy to advise you!

Arrange a non-binding consultation today.

Tobias Bunse

Phone: +49 (2174) 7848 - 0
E-Mail: info@kaehler-armaturen.de

Our ball valves for district heating: products in detail

The following products are available in our online shop. Further sizes and versions on request.

Filter products

Ball Valve, Flanges, with Lever
Ball Valve, Flanges, with Lever
NAVAL-No. 286562 DN100 PN16
Ball valves NAVALSTEAM,
Ball valves NAVALSTEAM,
all welded construction,
Ball valves NAVALSTEAM,
Ball valves NAVALSTEAM,
all welded construction,
KÄHLER Balanc. Valve FL/FL DN015 PN25 rb Steel K X
KÄHLER Balanc. Valve FL/FL DN015 PN25 rb Steel K X
Balancing ball valve X-Series flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143015X Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN020 PN25 rb Steel K X
KÄHLER Balanc. Valve FL/FL DN020 PN25 rb Steel K X
Balancing ball valve X-Series flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143020X Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN025 PN25 rb Steel K X
KÄHLER Balanc. Valve FL/FL DN025 PN25 rb Steel K X
KÄHLER Balanc. Valve FL/FL DN025 PN16 rb Steel K X Balancing ball valve X-Series flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143025X Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN032 PN25 rb Steel K X
KÄHLER Balanc. Valve FL/FL DN032 PN25 rb Steel K X
Balancing ball valve X-Series flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143032X Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN040 PN25 rb Steel K X
KÄHLER Balanc. Valve FL/FL DN040 PN25 rb Steel K X
Balancing ball valve X-Series flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143040X Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN050 PN25 rb Steel K X
KÄHLER Balanc. Valve FL/FL DN050 PN25 rb Steel K X
Balancing ball valve X-Series flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143050X Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN065 PN16 rb Steel K
KÄHLER Balanc. Valve FL/FL DN065 PN16 rb Steel K
Balancing ball valve flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143065 Type Naval 265510V Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN065 PN25 rb Steel K
KÄHLER Balanc. Valve FL/FL DN065 PN25 rb Steel K
Balancing ball valve flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143065/25 Type Naval 265570V Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN080 PN16 rb Steel K
KÄHLER Balanc. Valve FL/FL DN080 PN16 rb Steel K
Balancing ball valve flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143080 Type Naval 265511V Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN080 PN25 rb Steel K
KÄHLER Balanc. Valve FL/FL DN080 PN25 rb Steel K
Balancing ball valve flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143080/25 Type Naval 265571V Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN100 PN16 rb Steel K
KÄHLER Balanc. Valve FL/FL DN100 PN16 rb Steel K
Balancing ball valve flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143100 Type Naval 265512V Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN100 PN25 rb Steel K
KÄHLER Balanc. Valve FL/FL DN100 PN25 rb Steel K
Balancing ball valve flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143100/25 Type Naval 265572V Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN125 PN16 rb Steel K
KÄHLER Balanc. Valve FL/FL DN125 PN16 rb Steel K
Balancing ball valve flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143125 Type Naval 265513V Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN125 PN25 rb Steel K
KÄHLER Balanc. Valve FL/FL DN125 PN25 rb Steel K
Balancing ball valve flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143125/25 Type Naval 265573V Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN150 PN16 rb Steel K
KÄHLER Balanc. Valve FL/FL DN150 PN16 rb Steel K
Balancing ball valve flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143150 Type Naval 265514V Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve FL/FL DN150 PN25 rb Steel K
KÄHLER Balanc. Valve FL/FL DN150 PN25 rb Steel K
Balancing ball valve flanged ends EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 143150/25 Type Naval 265574V Operation conditions: acc. to Datasheet incl. precision control knop
KÄHLER Balanc. Valve WE/WE DN015 PN25 rb Steel K X
KÄHLER Balanc. Valve WE/WE DN015 PN25 rb Steel K X
Balancing ball valve X-Series welding ends fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 140015X Operation conditions: -20°C - +120°C incl. precision control knop
KÄHLER Ball Valve FL/FL DN015 PN40 rb Stainless st
KÄHLER Ball Valve FL/FL DN015 PN40 rb Stainless st
Shut-off ball valve X-Series flanged endsEN1092-1 fully-welded construction reduced bore Body material: Stainless steel P235GH (1.4404) Ball material: Stainless steel AISI316L (1.4404) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel AISI316L (1.4404) Steam sealing: FPM Type Vexve 233015X Operation conditions acc. to data sheet incl. composite handle
KÄHLER Ball Valve FL/FL DN015 PN40 rb Steel H X
KÄHLER Ball Valve FL/FL DN015 PN40 rb Steel H X
Shut-off ball valve X-Series flanged ends acc. to EN1092-1 fully-welded construction reduced bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Type Vexve 103015X Operation conditions acc. to data sheet incl. composite handle
KÄHLER Ball Valve FL/FL DN015 PN40 vD Steel H
KÄHLER Ball Valve FL/FL DN015 PN40 vD Steel H
Shut-off ball valve flanged ends acc. to EN1092-1 fully-welded construction full bore Body material: Steel P235GH (1.0345) Ball material: Stainless steel X5CrNi18-10 (1.4301) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel X8CrNiS18-9 (1.4305) Steam sealing: FPM Typ Vexve 153015X Operation conditions acc. datasheet incl. handle
KÄHLER Ball Valve FL/FL DN020 PN40 rb Stainless st
KÄHLER Ball Valve FL/FL DN020 PN40 rb Stainless st
Shut-off ball valve X-Series flanged endsEN1092-1 fully-welded construction reduced bore Body material: Stainless steel P235GH (1.4404) Ball material: Stainless steel AISI316L (1.4404) Spring-loaded ball sealing made of reinforced PTFE Stem: Stainless steel AISI316L (1.4404) Steam sealing: FPM Type Vexve 233020X Operation conditions acc. to data sheet incl. composite handle

FAQ – Häufig gestellte Fragen zu Fernwärme-Armaturen

Was sind Fernwärmearmaturen?
Fernwärmearmaturen sperren, regeln, entleeren und entlüften das Heizwasser auf dem Weg vom Erzeuger über Haupt- und Verteilleitungen bis zum Hausanschluss. Sie müssen dauerhaft dicht sein, hohen Temperaturen und Druckschwankungen standhalten und oft erdverlegt oder gedämmt eingebaut werden. Typische Fernwärmearmaturen sind vollverschweißte Kugelhähne, zapfengelagerte Kugelhähne für große Nennweiten, Absperrklappen, Anbohr- und Bedarfsanschlusshähne, Regulierkugelhähne sowie Entleerungs- und Entlüftungshähne.
Was zeichnet die Fernwärme-Kugelhähne von Vexve aus?
Vexve entwickelt seine Armaturen seit Jahrzehnten für Fernwärme- und Fernkältenetze. Die vollverschweißten Kugelhähne mit schwimmender Kugel haben ein Gehäuse aus Druckbehälterstahl, eine Edelstahlkugel mit federbelasteten, graphitverstärkten PTFE-Dichtschalen und eine dreifach gedichtete, ausblassichere Spindel. Sie dichten bi-direktional nach Leckrate A, sind wartungsfrei, gut isolierbar und vergleichsweise leicht. Das reduziert Wärmeverluste und erleichtert den Einbau auf der Baustelle. KÄHLER ist Generalvertretung von Vexve für Deutschland.
Welche Armaturen braucht ein Fernwärme-Hausanschluss?
Ein typischer Hausanschluss beginnt mit einem Abzweig von der Verteilleitung, oft über einen Anbohr- oder Bedarfsanschlusshahn. Im Gebäude folgen die Hauptabsperrarmaturen für Vor- und Rücklauf, meist vollverschweißte Kugelhähne in kleinen Nennweiten, dazu Entleerungs- und Entlüftungshähne und ein Schmutzfänger vor der Übergabestation. Je nach Netz kommt ein Regulierkugelhahn hinzu. Welche Armaturen gefordert sind, regeln die technischen Anschlussbedingungen des Netzbetreibers.
Welche Nennweiten und Druckstufen sind für die Fernwärme lieferbar?
Vollverschweißte Fernwärme-Kugelhähne von Vexve gibt es von DN10 bis DN1200 in PN16, PN25 und PN40. Bis DN500 kommen Kugelhähne mit schwimmender Kugel zum Einsatz, von DN125 bis DN1200 zapfengelagerte Kugelhähne. Für den Erdeinbau gibt es Kugelhähne bis DN900, für Netzerweiterungen Anbohrkugelhähne bis DN200. Absperrklappen ergänzen das Programm von DN32 bis DN2200.
Was bedeuten vD und rD, und was ist in der Fernwärme sinnvoll?
vD steht für vollen Durchgang, rD für reduzierten Durchgang. Beim vollen Durchgang entspricht die Kugelbohrung etwa dem Rohrinnendurchmesser, der Druckverlust ist minimal und die Pumpenergie im Netz sinkt. Beim reduzierten Durchgang ist die Bohrung kleiner, die Armatur leichter und günstiger, der Strömungsverlust höher. Welche Variante gefordert ist, steht meist in den technischen Anschlussbedingungen des Netzbetreibers.
Welche Anschlussarten sind in der Fernwärme üblich?
Standard in Fernwärmenetzen sind beidseitige Schweißenden, weil sie dauerhaft dicht sind und direkt an das Stahlmediumrohr angeschweißt werden. In Stationen und Anlagen kommen Flanschanschlüsse nach EN 1092-1 hinzu, im Gebäude auch Innen- oder Außengewinde. Kombinationen wie Schweißende/Flansch oder Schweißende/Innengewinde erleichtern Übergänge. Bei Entleerungshähnen ist Schweißende/Außengewinde mit Kette und Kappe verbreitet.
Wie werden Fernwärmearmaturen betätigt?
Kleine Kugelhähne werden per Handhebel geschaltet, größere per Handgetriebe. Anbohr- und Bedarfsanschlusshähne haben einen Außensechskant mit Stellungsanzeige, erdverlegte Kugelhähne einen Schaft für den T-Schlüssel. Für fernbediente Trennstellen, etwa in Schächten oder großen Verteilleitungen, gibt es elektrische, pneumatische und hydraulische Antriebe. Ein 90°-Anschlag verhindert bei allen Kugelhähnen das Durchdrehen der Kugel.
Wann werden zapfengelagerte Kugelhähne in der Fernwärme eingesetzt?
Zapfengelagerte Kugelhähne sind für große Nennweiten von DN125 bis DN1200 und hohe Beanspruchung gedacht, etwa an Erzeugungsanlagen, Transportleitungen und wichtigen Trennstellen. Die fest gelagerte Kugel senkt das Drehmoment und erhöht die Stabilität. Die Double-Block-and-Bleed-Funktion erlaubt eine Dichtheitsprüfung unter Druck, der Single-Piston-Effekt leitet Überdruck aus dem Gehäuse ab. Hebeösen und Standfuß erleichtern den Einbau, ober- und unterirdisch.
Können Fernwärmearmaturen direkt erdverlegt werden?
Ja. Erdverlegte Kugelhähne von Vexve werden nach EN 488 hergestellt und geprüft und ohne Schacht direkt im Erdreich eingebaut. Betätigt werden sie über einen Schaft mit Standard- oder individueller Länge per T-Schlüssel, Handgetriebe oder Antrieb. Passende Entlüftungs- und Entleerungshähne gibt es für den Erdeinbau. Der Verzicht auf Schächte spart Platz, besonders in dicht bebauten Innenstädten.
Wie werden neue Abnehmer ohne Abschaltung an ein Fernwärmenetz angeschlossen?
Mit einer Anbohrung unter Betriebsdruck und Temperatur. Dazu wird ein Anbohrkugelhahn auf die Leitung geschweißt, anschließend bohrt das NAVAL-Anbohrgerät die Leitung durch den geöffneten Hahn an. Das Netz muss nicht entleert werden, andere Abnehmer bleiben versorgt. Möglich sind Abgänge von DN20 bis DN200 bis 25 bar und 200 °C. KÄHLER liefert Anbohrgeräte und Anbohrkugelhähne, schult Monteure und bietet Anbohrungen als Service zum Festpreis an.
Stellt KÄHLER Ausschreibungstexte für Fernwärmearmaturen bereit?
Ja. KÄHLER stellt Ausschreibungstexte für Leistungsverzeichnisse bereit, gegliedert nach Einbausituation: Hausanschluss und Verteilung (DN15 bis DN65), Schachteinbau mit Schweißenden oder Flansch, Erdeinbau mit schwimmend oder zapfengelagerter Kugel sowie Anbohrtechnik und Anbohrservice. Dazu gibt es 2D- und 3D-Zeichnungen, Datenblätter und Zeugnisse. Planungsbüros und Stadtwerke erhalten die Unterlagen auf Anfrage digital.
Worauf kommt es bei der Dämmung von Fernwärmearmaturen an?
Armaturen sind Wärmebrücken und müssen lückenlos gedämmt werden, damit Wärmeverluste und in Kältenetzen Kondensation vermieden werden. Günstig sind kompakte Gehäuse, kurze Spindeln und Betätigungen außerhalb der Dämmung. Anbohr- und Bedarfsanschlusshähne haben deshalb eine niedrige Spindel, bei der X-Serie ist der Handhebel zugleich Spindelverlängerung. Bei Anbohrkugelhähnen empfiehlt KÄHLER, die Spindelkappe vor dem Dämmen dicht zu verschweißen.
Wie schnell liefert KÄHLER Fernwärmearmaturen?
Gängige Fernwärme-Kugelhähne, Anbohr- und Bedarfsanschlusshähne, Entleerungshähne, Schmutzfänger und Anbohrzubehör sind ab Lager in Burscheid lieferbar. Angebote erstellt KÄHLER in der Regel innerhalb von zwei Stunden, spätestens am nächsten Werktag. Sonderausführungen werden meist in zwei bis drei Wochen geliefert. Für Rahmenverträge und Hausanschlussprogramme stimmt KÄHLER mit Stadtwerken eine Lagerbevorratung ab.
Welche Armaturen eignen sich für Fernkälte?
In Fernkältenetzen kommen dieselben vollverschweißten Kugelhähne zum Einsatz wie in der Fernwärme, ausgelegt für Klima-Kaltwasser. Wichtig sind eine dampfdichte Dämmung und kurze Spindeln, damit sich kein Kondensat an kalten Bauteilen bildet. Für Wasser-Glykol-Gemische oder offene Kühlsysteme sind Edelstahlkugelhähne eine Option. Auch das Anbohren unter Druck und die iSense-Netzüberwachung von Vexve sind für Fernkältenetze ausgelegt.
Wie lassen sich Fernwärmenetze digital überwachen?
Mit der iSense-Produktreihe von Vexve werden Druck, Temperatur, Durchfluss, Schachtzustand und Leckagen im erdverlegten Netz gemessen und per LoRaWAN oder NB-IoT an den Cloud-Dienst iSense Online übertragen. Die Geräte arbeiten mit Batterie oder mit Strom aus der Vorlaufwärme und lassen sich in Bestandsnetzen nachrüsten. KÄHLER plant die Messstellen, installiert die Systeme und betreut den Betrieb.
Fully Welded Ball Valves
Fully Welded Ball Valves
Hot Tapping Technology
Hot Tapping Tools
Trunnion Mounted Ball Valves
Trunnion Mounted Ball Valves